+-------------------------------------------------------------------------------+ | This file include all information's about Changes in the different Versions. | | The Value in the round brackets behind the version number is the release date.| +-------------------------------------------------------------------------------+ Version 2.3.18 (27/April/2009) Error with Tracefield FileName fixed. Version 2.3.17 (26/July/2008) Removed Support for Q-DAS Portlock Option. License will be checked through a separate license file. Version 2.3.16 (06/February/2008) Support for QDAS portlock option Version 2.3.15 (05/February/2007) Added support for K2004 We insert K2004/0 0 in the dfd or dfq file Version 2.3.14 (15/January/2007) - Support for the following Tracefields: Name Value QDAS 0 QDAS 1 QDAS E This will help to support loops with the Q-DAS Converter. Version 2.3.13 (10/January/2007) - Release for PC-DMIS Version 4.1 (no support for Feature Control Frames --- you nedd to use Legacy Dimensions) Version 2.3.12 (27/April/2006) - RegKey for K_Fields_Settings included two \ - Resolved a problem with the setup dialogs and default user rights. Version 2.3.11 (09/April/2006) - Support for Hungarian language. Version 2.3.10 (18/March/2006) - Add a rule for GM file names - Add a supported Trace filed with the name "FileName". The value will be used together with both file name rules. - The grouping of true position dimensions (using check "Use Q-DAS Position Calculation") is now only working, if the true position dimension is using 2 ordinates. - Added an operator decision, how the converter should proceed, if the part program was canceled. Version 2.3.9 (11/March/2006) - Optional Support of Statistic commands STATS/ON, STATS/OFF and STATS/TRANSFER,DIRECTORY={Target directory} with ONLINE mode. - Support of PC-DMIS 4.0 (only part programs wihout Feature Control Frames). The 4.0 release must be newer then March 8 2006 Version 2.3.8 (23/February/2006) - Window was not minimized, if the Converter was startet from an external Command in the part program. Version 2.3.7 (19/February/2006) - Complete Spanish and Portuguese language - Resize of the Main window to fit better for the different translations. Version 2.3.6 (31/January/2006) - Now the filename can start also with date and time (format changed to yyyy-mm-dd) IMPORTANT: CHECH YOUR SETTINGS FOR THE FILE NAME IN THE SETUP - Check in the program settings allows to minimize the window during Online process Version 2.3.5 () - <<# left in the comment (if the Comment is used for K2002) suppresses the output of the dimension in the Q-DAS ASCII file (request of MIELE) Version 2.3.4 (25/September/2005) - French and Italian language. - New Function fctPcdRelease implemented. This function release all the PC-DMIS Objects before the converter will be closed. - Morde detailed Status Bar Informations during the Upload implemented. - A UploadDebug.txt will be created during the file upload in the target folder. - Problem in the form load of the advanced settings dialog resolved. Version 2.3.3 (24/August/2005) - Output for K0005, K2006: If no global Value and no individual Value is set, the Keys will not send to the Q-DAS ASCII file. - Values for the Q-DAS ASCII file name are now used from the Converter MainWindow form. Before they was used from the PC-DMIS Automation code. The problem was, if the PC-DMIS part program was closed before the Q-DAS ASCII file was generated, the values was no longer available. Version 2.3.2 (24/July/2005) - Extended language file for modPcdConnect - Correct size of the frmMain Version 2.3.1 (18/July/2005) - Support for K1021 as Tracefield - Support for K1022 as Tracefield - Support for K1031 as Tracefield - Support for K1032 as Tracefield - Support for K1041 as Tracefield - Support for K1042 as Tracefield - Support for K1052 as Tracefield - Support for K1203 as Tracefield - K-Field Output only, if Value exist Version 2.3.0 () - ComboBox 1010 List values changes now with the language - After a new installation the program will ask for the folder of the catalog file. - Translation of some important Information fields. - If PC-DMIS is not active, the converter will not longer try to start PC-DMIS - Warning, if the PC-DMIS header is not complete. This values will be used for K1001, K1002 and K1004. - All forms will be shown in the task bar. - New K-Field Support for K1209. The values must be stored in a "local catalog file". - Registry setting HKEY_LOCAL_MACHINE\SOFTWARE\DEAGERMANY\PCDQDAS\Settings\ValueFilePath defines where the "local catalog files" are stored. - Characteristic Number can be a counter value in the order, how the Dimensions are in the PC-DMIS part program stored. Registry Setting: HKEY_LOCAL_MACHINE\SOFTWARE\DEAGERMANY\PCDQDAS\Settings\Dimension Name Value: 0 (old style) Value: -1 (Counter Value) - Characteristic Name can use the PC-DMIS Comment in front of the dimension command. Support for K2900 is voided with this setting. Registry Setting: HKEY_LOCAL_MACHINE\SOFTWARE\DEAGERMANY\PCDQDAS\Settings\Dimension Name Value: 0 (old style) Value: -1 (Use PC-DMIS Comment command text) - If the converter started Online from the PC-DMIS part program, the default value for the number of decimal places was not read from the WAI Registry Key. - Process parameter will be written only, if really a value was set. - The check in the menu for language selection show sometimes a wrong position. Version 2.2.8 (03/May/2005) News: - Advanced list of supported Trace commands. Version 2.2.7 (02/May/2005) Fixes: - Empty fields in catalog file will be not longer a problem. Example: K4252/6 Fixture 6 K4253/6 Fixture Number 6 K4252/7 K4253/7 K4252/101 Sp 01 K4253/101 Spindle 01 Version 2.2.6 (26/April/2005) Fixes: - Output for K0009 was not working - Special Version for PC-DMIS 3.5 Version 2.2.5 (31/March/2005) Fixes: - Problem fixed, if we used more then one start argument Version 2.2.4 (26/March/2005) News: - Change in the form for the process parameter selection Version 2.2.3 (17/March/2005) Fixes: - If subfolder PartData is missing, the converter will create this folder now automatically - Before starting Offline all labels are cleared. - Fixed a problem with unloaded Object during Offline conversion - Changed to Object Catalog of PC-DMIS 3.7 - Add. warning, if Object Catalog is from a different Version as the current PC-DMIS Version. Version 2.2.2 (10/March/2005) Fixes: - Problem with Command /i Version 2.2.1 (only BETA) Fixes: - Filter for Comments in Catalogfile: // Comment text - Input Dialog for Q-DAS Data: ComboBox Style changed to Dropdown List. The operator can use only existing items in the list. - Input Dialog for Q-DAS Data: Software crash, if a Catalog was selected. News: - New K-Field Support: K2061 and K0011 for Process Parameter Version 2.1.18 (06/February/2005) Fixes: - Bug in License Information dialog - comdlg32.ocx included in Setup Version 2.1.17 (03/January/2005) News: - Multi Language Interface (including English, German, French, Italian, Czech, Spanish and Portuguese language) Version 2.1.16 (16/December/2004) Fixes: - Problem with Output Option=None or Prot - Bigger box size for Feature1, Feature2, Feature3 and PC-DMIS Part Information Version 2.1.15 (20/November/2004) Fixes: - Start option /a /A /i /I have not worked in Version 2.1.14 - If no item is selected in the list boxes for the Q-DAS ASCII file name, the converter will ignore this section now. Version 2.1.14 (08/November/2004) News: - Selectable target folder for Q-DAS® ASCII files from the part program - Possibility to use one default file (default.cfg) for Q-DAS data together with all part programs - An additional Trace Command for the operator was added (K0008). The value must be an integer value (regarding the value in the Q-DAS Catalog). - Change in K2001 and K2002 for the compatibility with the Converter Version 1. This change is working only, if the check box "Use Q-DAS Converter V. 1 Axis Designations" in the Setup Dialog is selected. Version 2.1.13 (02/November/2004) News: - Measured value for True Position Dimension use now the deviation value. Version 2.1.12 (06/October/2004) News: - License Request is now included in the software. Version 2.1.11 News: - Company Name changed from DEA - Brown & Sharpe GmbH to Hexagon Metrology - Selected language will be checked - Problem with upload fixed (If target folder did not exist, ther was no warning). Version 2.1.10 (19/September/2004) News: - Trace Comands and decimal precision commands can be placed between the Comment for the dimension and the Dimension Command - Support for Trace Commans for K2001, K0053, K1053 and K0012. - Support for Axis Designations from PC-DMIS Q-DAS Converter Version 1.x.x (MultiLanguage) Version 2.1.9 (02/August/2004) Fixes: - K2022 value was 0 if there was used different Modal Commands in the part program. Version 2.1.8 (02/August/2004) Fixes: - Problem with array size IndividuelleZusatzdaten Version 2.1.7 (31/August/2004) Fixes: - This version use better default settings - Fix for Registry Setting UseQPos. (Problem was only, before you have select the first time the value inside of the setup) Version 2.1.6 (30/August/2004) Fixes: - Problem with array size IndividuelleZusatzdaten News: - All captions as variables Version 2.1.5 (28/August/2004) Fixes: - K-fields, for which no value was entered, are not longer print in the DXF file. - All Dialogs are using now the same Font (ARIAL) - Help Button removed from the symbol bar - Check Box for K1007 did not show the correct value before - Setup Dialof for K-Fields use now the customized setting for the K-Field description - During the Online conversion the K2031 value was wrong Version 2.1.4 (27/August/2004) News: - Support for TRACE commands for K2005/0, K2005, K2006/0 and K2006 - True Position ordinates will get a default value (1) for K2005 (Characteristic class), the programmer can overwrite the default value with the TRACE command - Removed the possibility to change the control item from the Add. Q-DAS Data Dialog for individual Characteristic - Number of decimal places will be read automatically from the PC-DMIS part program - Setup dialog to enable/disable K-Fields in the operator interface - A message box will warn the operator (only if "Use Q-DAS Position Calculation" is active), if more then two axis are used for true position - The output for the event cataog (K-Field K2060) is by default: K2060/0 0 - Check OOT Values will open a operator message with the number of OOT values - The back colour of the "Out of Tol" label will use red or green colour - depending on the value Version 2.1.3 (23/August/2004) Fixes: After closing the part program the converter close automatically the connection. Key UseCFG was not defined automatically after installation. K0006, K1010, K2005 was sending a -1 if the operator didn't select a value. News: With the startoption /i or /I you can start the converter for Inline systems. No operator input is requested. Version 2.1.2 (09/July/2004) News: Internal Change of the product name (PC-DMIS - Q-DAS Coverter to PC-DMIS - Q-DAS Converter) Registry setting: „CatalogPathName“. You can use this setting, if you like to use a Q-DAS catalog, which is not located in the Installation folder of the software. Fixes: K2002 value was different during ONLINE or OFFLINE coversion All values in the list will be checked for the Q-DAS ASCII output Version 2.1.1 (29/June/2004) Fixes: Date and Time format for the file name. Problem if no comments exists during the Online conversion. Version 2.1.0 (27/June/2004) First official Release.